-PEAK<br />
1) Place the part to be checked in gage position.<br />
2) Press RST.<br />
3) Rotate the part or reposition the gage depending on the particular application. The<br />
bargraph and alphanumeric displays will show the minimum reading since the RST<br />
button was pressed.<br />
For example to check the maximum diameter of a hole:<br />
1) Place the part in an air plug connected to the <strong>Accusetter</strong> II .<br />
2) Press RST.<br />
3) Rotate the part through at least one revolution.<br />
4) Read the -PEAK value from the alphanumeric display or the bargraph.<br />
NOTE: The <strong>Accusetter</strong> can be programmed to automatically reset the display using AUTO<br />
RST menu. See System Programming, Auto Reset.<br />
TIR<br />
1) Place the part to be checked in gage position.<br />
2) Press RST.<br />
3) Rotate the part or reposition the gage depending on the particular application. The<br />
bargraph and alphanumeric displays will show the difference between the maximum<br />
and minimum reading since the RST button was pressed.<br />
For example to check roundness of a hole:<br />
1) Place the part on an air plug connected to the <strong>Accusetter</strong> II .<br />
2) Press RST.<br />
3) Rotate the part through at least one revolution.<br />
4) Read the TIR value from the alphanumeric display or the bargraph.<br />
NOTE: The <strong>Accusetter</strong> can be programmed to automatically reset the display using AUTO<br />
RST menu. See System Programming Auto Reset.<br />