Zero Master Calibration<br />

1) From RUN mode, press the CAL button.<br />

2) Rotate the ENTER button until "ZERO" is displayed and then press ENTER. "INS<br />

ZERO" will be displayed.<br />

NOTE: All checks that are programmed with a ZERO master will be turned "ON"<br />

by default and will therefore be gaged at the same time. If the ZERO masters are to<br />

be gaged separately then the checks must be turned "OFF" manually from the "CHK<br />

SEL" menu.<br />

3) Place the ZERO master into gage position and press ENTER. "GAGE ZERO" will be<br />

displayed.<br />

4) Press the ENTER button. The ZERO master will be gaged and then the display will<br />

update to "MASTERED" if the calibration was successful. If the calibration was<br />

successful the gage is ready to measure parts, see Operation. Remove the ZERO<br />

master and press RUN. If the calibration was not completed successfully then see the<br />

Troubleshooting section of this manual.<br />