PROGRAMMING - SYSTEM OPTIONS<br />

Buss In/Buss Out Setup<br />

Note: For multiple check and multiple fixture programs BUSS IN and BUSS OUT<br />

options are available, for column to column communications. These signal are used<br />

with the I/O "A" and "B" 25 pin connections.<br />

1) From the COMM menu rotate the enter button to display "BUS OUT" and then<br />

press ENTER.<br />

2) Rotate the ENTER button to select the name of the check or fixture to be bussed<br />

out and then press ENTER.<br />

3) "BUS OUT" will display. Rotate the enter button to display "BUS IN" and<br />

press the ENTER button.<br />

4) Rotate the ENTER button to select "INPUT C" or "INPUT D" and press the<br />

ENTER button.<br />

5) Rotate the ENTER button to select "AIR" if the signal to be bussed in is from an<br />

air gage or "ELEC" if the signal to be bussed in is from an electronic gage.<br />

6) Press the ENTER button.<br />

7) Press the RST button. If a second bussed in signal is to be set up repeat steps 4<br />

- 6.<br />

8) When all inputs have been setup press the RUN button.<br />

9) Rotate the ENTER button to display "SAVE" and then press ENTER to save the<br />

current setup.<br />

3-41