PROGRAMMING - MULTIPLE CHECK MEASUREMENT<br />
Multiple Check Programming<br />
Programming SETUP Options<br />
1) With the column in RUN mode, Press the ENTER button and then rotate the ENTER<br />
button until "SETUP" is displayed.<br />
2) Press the ENTER button.<br />
3) Rotate the ENTER button to select "XDUCER", "DEFINE" or "PART NAME" and<br />
then press the ENTER button.<br />
XDUCER Menu<br />
Signal <strong>Co</strong>nditioning<br />
(Note: These parameters will be automatically set by module<br />
recognition for E9310, E9320, E9330, or E9340 modules)<br />
1) Rotate the ENTER button until SIG COND is displayed and then press<br />
the ENTER button.<br />
2) Rotate the ENTER button to select "AIR" or "ELEC" and then press the<br />
ENTER button.<br />
a) If "ELEC" was selected then rotate the ENTER button to select<br />
"GAIN 1X" or "GAIN 10X" and then press the ENTER button to<br />
return to the Xducer menu.<br />
b) If "AIR" was selected then rotate the ENTER button to select LOW<br />
MAG, MED MAG, or HIGH MAG and then press ENTER to return<br />
to the Xducer menu.<br />
Scale<br />
1) Rotate the ENTER button until SCALE is displayed and then press the<br />
ENTER button.<br />
2) Rotate the ENTER button to select "INCH" or "METRIC".<br />
3) Press the ENTER button and the <strong>Accusetter</strong> will return to the Xducer<br />
menu and display "SCALE".<br />
3-24