2.10 E9340 (2) Channel A/E Signal <strong>Co</strong>nditioning Module<br />

The E9340 module is a two channel air/electric amplifier which processes pneumatic<br />

information from the air tooling and delivers a conditioned signal to the controller board<br />

of the <strong>Accusetter</strong> II. The module is mounted in the lower bay of the <strong>Accusetter</strong> II<br />

The A/E module also contains a ZERO adjustment knob and a MAG adjustment knob for<br />

each input for initial input setup to accommodate the air tooling used..<br />

The air tooling is connected to the air fitting on the front panel of the module. The<br />

recommended length of air line from the module to the air tool is no more than six feet.<br />

A minimum of 60 psi air must be supplied to the filter/regulator assembly on the rear of<br />

the unit. The regulator is factory set to 44 psi.<br />

A jumper strip labeled "A OUT" and "B OUT" provides the option to select a pin, 1 -6,<br />

to output a high level (+/-1.84VDC) signal(s) to the I/O connectors.<br />

Power to the column must be turned off prior to installing or removing a signal<br />

conditioning module.<br />

Refer to the Advanced Operation, A/E Module Setup section for additional<br />

information on jumper settings and see Basic Operation, Setting A/E Mag & Zero<br />

for additional information on setting Mag and Zero for a particular application.<br />

Figure 2.10 - E9340 (2) Channel AE Signal <strong>Co</strong>nditioning Module<br />

2-14