4.5 Input/Output Board<br />

<strong>Accusetter</strong> I/O Board (P/N 5911013) Functions<br />

The <strong>Accusetter</strong> I/O board provide the user with various I/O functions. All I/O functions<br />

are optically isolated from the rest of the <strong>Accusetter</strong> electronics and are available at the<br />

rear panel I/O A and B connectors.<br />

Summary of I/O signals<br />

Inputs<br />

• Air Shutoff Present: <strong>Co</strong>ntrol line to detect connection of automatic air shutoff<br />

assembly #5913250.<br />

• Footswitch: <strong>Co</strong>ntrol line to externally send data via the RS232C port.<br />

• TIR/PEAK Reset: <strong>Co</strong>ntrol line to externally reset TIR or PEAK detectors.<br />

• Status/Class Request: <strong>Co</strong>ntrol line to select output of over, good, under relay or<br />

class bit 0, 1, or 2. See Outputs below.<br />

Inputs are activated by applying a 5-24 VDC signal to the appropriate input line. These<br />

signals must be positive in respect to the Isolated <strong>Co</strong>mmon P24. See “Typical<br />

<strong>Co</strong>nnections” section for examples.<br />

Outputs<br />

• Air Off: Shuts off air flow to tooling using automatic air shutoff assembly<br />

#5913250.<br />

• Over Relay/Class Bit 0: Normally open Over relay or classification bit 0<br />

• Good Relay/Class Bit 1: Normally open Good relay or classification bit 1<br />

• Under Relay/Class Bit 2: Normally open Under relay or classification bit2<br />

• Class Bit 3: Classification bit 3<br />

• Class Bit 4: Classification bit 4<br />

Outputs are normally open Solid State Relays (SSR) and can sink or source current up to<br />

250ma (AC, DC). Maximum load voltage is 120V. Typical “on resistance” (Ron) is 5<br />

ohms. All outputs are referenced to the Relay Output <strong>Co</strong>mmon P19. See “Typical<br />

<strong>Co</strong>nnections” section for examples.<br />