<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />
S – S-Register Access<br />
Read <strong>Command</strong><br />
<strong>AT</strong>SXX[x[x]]<br />
Examples<br />
<strong>AT</strong>S00<br />
<strong>AT</strong>S0AE<br />
<strong>AT</strong>S1812<br />
XX is the S-Register which is to be read.<br />
As an option for all 16 bit registers it is also<br />
possible to address an individual bit only by<br />
specifying the bit number [x]. For all 32 bit<br />
registers it is possible to address an<br />
individual bit by specifying the bit number in<br />
hexadecimal [xx]<br />
Write <strong>Command</strong><br />
<strong>AT</strong>SXX[x[x]]=[,]<br />
Response<br />
<br />
OK<br />
or ERROR:<br />
The module displays the contents of S-register xx<br />
or an error message, where <br />
represents the error code explained in section 3.<br />
All 16- and 32-bit registers can also be accessed<br />
bit by bit. In order to do this [x[x]] may specify the<br />
bit which is to be read. The result when reading a<br />
single bit will always be 0 or 1.<br />
Response<br />
OK or ERROR:<br />
Examples<br />
<strong>AT</strong>S00=3FFC<br />
<strong>AT</strong>S0AE=1:password<br />
Notes<br />
Some S-Registers require a password for<br />
write access. See S-Register description for<br />
details. The default password for R3xx is<br />
“password”.<br />
Some S-Registers are read-only and will<br />
return an error if you are trying to write to<br />
them.<br />
When writing an individual bit by specifying<br />
[x[x]], can only be either 0 or 1.<br />
The data is written to S-register number XX and if<br />
applicable stored in non-volatile memory. The data<br />
format for each individual S Register is given in the<br />
S-Register description.<br />
represents the error code explained in<br />
section 3.<br />
For all 16- and 32-bit registers individual bits can<br />
also be set or cleared by specifying the bit using<br />
hexadecimal [x[x]] and setting it to either 0 or 1.<br />
SW release R300 ●<br />
©2012 Telegesis (UK) Ltd - 15 - <strong>AT</strong> <strong>Command</strong> <strong>Manual</strong> (Rev 3.08)