<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />
4 S-Registers<br />
Most S-Registers of the ETRX2 and ETRX357 can be read and written locally as well as remotely.<br />
The S-Registers are summarised in the table below.<br />
S-Register Overview Local R/W Remote R/W<br />
S00 Channel Mask ( / ) ( / )<br />
S01 Transmit Power Level ( / ) ( / )<br />
S02 Preferred PAN ID ( / ) ( / )<br />
S03 Preferred Extended PAN ID ( / ) ( / )<br />
S04 Local EUI ( /-) ( /-)<br />
S05 Local NodeID ( /-) ( /-)<br />
S06 Parent‟s EUI ( /-) ( /-)<br />
S07 Parent‟s NodeID ( /-) ( /-)<br />
S08 Network Key 1 (-/ ) (-/ )<br />
S09 Link Key 1 (-/ ) (-/ )<br />
S0A Main Function 1 ( / ) ( / )<br />
S0B User Readable Name 1 ( / ) ( / )<br />
S0C Password 1 ( / ) ( / )<br />
S0D Device Information ( /-) ( /-)<br />
S0E Prompt Enable 1 ( / ) ( / )<br />
S0F Prompt Enable 2 ( / ) ( / )<br />
S10 Extended Function ( / ) ( / )<br />
S11 Device Specific ( / ) ( / )<br />
S12 UART Setup ( / ) ( / )<br />
S13 Pull-up enable ( / ) ( / )<br />
S14 Pull-down enable ( / ) ( / )<br />
S15 I/O Configuration ( / ) ( / )<br />
S16 Data Direction of I/O Port (volatile) ( / ) ( / )<br />
S17 Initial Value of S16 ( / ) ( / )<br />
S18 Output Buffer of I/O Port (volatile) ( / ) ( / )<br />
S19 Initial Value of S18 ( / ) ( / )<br />
S1A Input Buffer of I/O Port (volatile) ( /-) ( /-)<br />
S1B Special Function pin 1 (volatile) ( / ) ( / )<br />
S1C Initial Value of S1B ( / ) ( / )<br />
S1D Special Function Pin 2 (volatile) ( / ) ( / )<br />
S1E Initial Value of S1D ( / ) ( / )<br />
S1F A/D1 (ETRX3: ADC0) ( /-) ( /-)<br />
S20 A/D2 (ETRX3: ADC1) ( /-) ( /-)<br />
S21 A/D3 (ETRX3: ADC2) ( /-) ( /-)<br />
S22 A/D4 (ETRX3: ADC3) ( /-) ( /-)<br />
S23 Immediate functionality at IRQ0 ( / ) ( / )<br />
S24 Immediate functionality at IRQ1 ( / ) ( / )<br />
S25 Immediate functionality at IRQ2 ( / ) ( / )<br />
S26 Immediate functionality at IRQ3 ( / ) ( / )<br />
1 Password Protected Registers<br />
©2012 Telegesis (UK) Ltd - 53 - <strong>AT</strong> <strong>Command</strong> <strong>Manual</strong> (Rev 3.08)