<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />
S4E – End Device Poll Timeout<br />
Description<br />
Register in a parent defining the amount of<br />
time after which an SED or ZED times out of<br />
its parent‟s child table if it has not polled<br />
Register in an SED or ZED defining the<br />
amount of time after which it reports<br />
LostPAN when it loses the parent<br />
Operations<br />
R/W LOCAL<br />
R/W REMOTE<br />
Parameters<br />
XXYY<br />
Where YY is the timeout in seconds left-shifted by<br />
XX (YY * 2^XX). The default number results in a<br />
timeout of 5 Minutes, whereas the maximum<br />
number results in a timeout of approximately 48<br />
days.<br />
Maximum<br />
0EFF<br />
Becomes effective<br />
After Soft or Hard Reset<br />
Storage<br />
Non-Volatile<br />
Factory Default<br />
0605<br />
SW release R303 ●<br />
S4F – MAC Timeout<br />
Description<br />
Register defining the MAC timeout<br />
Operations<br />
R/W LOCAL<br />
R/W REMOTE<br />
Becomes effective<br />
After Soft or Hard Reset<br />
Parameters<br />
XXXX<br />
The Ember_Indirect_Transmission_Timeout is the<br />
amount of time in milliseconds that the MAC will<br />
hold a message for indirect transmission to a child.<br />
In addition to this is also the basis for the timeout<br />
after which an acknowledged unicast is nacked<br />
when no ack is received.<br />
Storage<br />
Non-Volatile<br />
Factory Default<br />
0BB8<br />
SW release R302 ●<br />