<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />
S1F – A/D1 Reading (ETRX3 series ADC0)<br />
Description<br />
The analogue reading of A/D1 (ETRX3<br />
series ADC0)<br />
ETRX3: Only when bit 13 (0x0D) of S15 is<br />
set, invalid otherwise<br />
Operations<br />
R LOCAL<br />
R REMOTE<br />
Becomes effective<br />
Instantly<br />
Parameters<br />
XXXX<br />
Representation<br />
The hexadecimal reading of the analogue input in<br />
mV (mV * 10 on the ETRX3) with respect to<br />
ground. The return value will be undefined in case<br />
the corresponding A/D converter has not been<br />
enabled.<br />
Range<br />
ETRX2: 0000 – 04B0 (0 – 1200)<br />
ETRX3: 0000 – 2EE0 (0 – 12000)<br />
Storage<br />
Instant Reading of analogue input<br />
SW release R300 ●<br />
S20 – A/D2 Reading (ETRX3 series ADC1)<br />
Description<br />
The analogue reading of A/D2 (ETRX3<br />
series ADC1)<br />
ETRX3: Only when bit 14 (0x0E) of S15 is<br />
set, invalid otherwise<br />
Operations<br />
R LOCAL<br />
R REMOTE<br />
Becomes effective<br />
Instantly<br />
Parameters<br />
XXXX<br />
Representation<br />
The hexadecimal reading of the analogue input in<br />
mV (mV * 10 on the ETRX3) with respect to<br />
ground. The return value will be undefined in case<br />
the corresponding A/D converter has not been<br />
enabled.<br />
Range<br />
ETRX2: 0000 – 04B0 (0 – 1200)<br />
ETRX3: 0000 – 2EE0 (0 – 12000)<br />
Storage<br />
Instant Reading of analogue input<br />
SW release R300 ●<br />
©2012 Telegesis (UK) Ltd - 75 - <strong>AT</strong> <strong>Command</strong> <strong>Manual</strong> (Rev 3.08)