<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />
+IDREQ – Request Node’s NodeID<br />
Execute <strong>Command</strong><br />
<strong>AT</strong>+IDREQ:[,XX]<br />
Response<br />
OK<br />
(ZDO)<br />
Where can be a node‟s EUI64, or<br />
address table entry and XX is an optional<br />
index number. In case an index number is<br />
provided, an extended response is requested<br />
asking the remote device to list its associated<br />
devices (ie children).<br />
Sends a broadcast to obtain the specified<br />
Device‟s NodeID and optionally also<br />
elements of its associated devices list.<br />
or ERROR:<br />
represents the error code explained in<br />
section 3.<br />
Prompt<br />
AddrResp:[,,]<br />
[nn. ]<br />
Use on<br />
All Devices<br />
In case of an error an errorcode other than 00 will<br />
be displayed and the prompt will end after the<br />
errorcode.<br />
Note<br />
is the Remote node‟s EUI64 and<br />
Providing FF as an address table entry is its NodeID. In case an extended<br />
addresses the local node<br />
response has been requested the requested<br />
NodeIDs from the associated devices list are listed<br />
as well.<br />
SW release R302 ●<br />
+EUIREQ – Request Node’s EUI64<br />
Execute <strong>Command</strong><br />
<strong>AT</strong>+EUIREQ:< Address>,[,XX]<br />
Where is the EUI64, NodeID or<br />
address table entry of the node which is to<br />
be interrogated about the node with the<br />
NodeID specified in . XX is an<br />
optional index number. In case an index<br />
number is provided, an extended response is<br />
requested asking the remote device to list its<br />
associated devices (ie children).<br />
Sends a unicast to obtain the specified<br />
device‟s EUI64 and optionally also elements<br />
of its associated devices list (extended<br />
response).<br />
Use on<br />
All Devices<br />
Note<br />
Providing FF as an address table entry<br />
addresses the local node<br />
Response<br />
SEQ:XX<br />
OK<br />
or ERROR:<br />
(ZDO)<br />
represents the error code explained in<br />
section 3.<br />
Prompt<br />
AddrResp:[,,]<br />
[dd. ]<br />
In case of an error an errorcode other than 00 will<br />
be displayed and the prompt will end after the<br />
errorcode.<br />
is the Remote node‟s EUI64 and<br />
is its NodeID. In case an extended<br />
response has been requested the requested<br />
NodeIDs from the associated devices list are listed.<br />
As with all unicasts after successful transmission<br />
the sequence number of the unicast is stated using<br />
the “SEQ:XX” prompt. When acknowledged (or<br />
not) the accompanying “ACK:XX” (or “NACK:XX”)<br />
prompt is displayed.<br />
SW release R302 ●<br />
©2012 Telegesis (UK) Ltd - 24 - <strong>AT</strong> <strong>Command</strong> <strong>Manual</strong> (Rev 3.08)