<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />
S07 – Parent’s 16-Bit NodeID<br />
Description<br />
The parent node‟s 16-bit NodeID.<br />
Operations<br />
R LOCAL<br />
R REMOTE<br />
Parameters<br />
<br />
Range<br />
0000-FFFF<br />
Note<br />
The return value is undefined for nodes<br />
without parents (coordinators and nodes that<br />
are not joined to a network). For an FFD,<br />
S07 is the ID of the node via which the local<br />
node joined the PAN<br />
Storage<br />
Factory Default<br />
n/a<br />
Non-Volatile<br />
SW release R300 ●<br />
S08 – Network Key<br />
Description<br />
The network key which can be written using<br />
the password. The default password for R3xx<br />
is “password”.<br />
Operations<br />
W LOCAL<br />
W REMOTE<br />
Write operation<br />
<strong>AT</strong>S08=:<br />
<strong>AT</strong>REMS:,08=:<br />
Becomes effective<br />
Only when establishing a PAN<br />
Range<br />
From 0 to 2 128 -1<br />
The 128-bit AES network key in hexadecimal<br />
representation (32 characters).<br />
When set to all 0‟s (default) a random network key<br />
is generated when establishing a PAN.<br />
This key is transmitted to all joining nodes and can<br />
be encrypted using the link key.<br />
Factory Default<br />
Storage<br />
00000000000000000000000000000000<br />
Non Volatile<br />
SW release R300 ●<br />
©2012 Telegesis (UK) Ltd - 59 - <strong>AT</strong> <strong>Command</strong> <strong>Manual</strong> (Rev 3.08)