<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />
+NODEDESC – Request Node’s Descriptor<br />
Execute <strong>Command</strong><br />
<strong>AT</strong>+NODEDESC:,<br />
Where is the EUI64, NodeID or<br />
Address table entry of the node which is to<br />
be interrogated about the node with the<br />
NodeID specified in .<br />
Sends a unicast to obtain the specified<br />
device‟s node descriptor.<br />
Response<br />
SEQ:XX<br />
OK<br />
or ERROR:<br />
(ZDO)<br />
represents the error code explained in<br />
section 3.<br />
Prompt (example)<br />
Use on<br />
All Devices<br />
Note<br />
Providing FF as an address table entry<br />
addresses the local node<br />
NodeDesc:,<br />
Type:FFD<br />
ComplexDesc:No<br />
UserDesc:No<br />
APSFlags:00<br />
FreqBand:40<br />
MacCap:8E<br />
ManufCode:1010<br />
MaxBufSize:52<br />
MaxInSize:0080<br />
SrvMask:0000<br />
MaxOutSize:0080<br />
DescCap:00<br />
In case of an error an errorcode other than 00 will<br />
be displayed and the prompt will end after the<br />
errorcode.<br />
is the Remote node‟s NodeID. In<br />
addition the node descriptor is displayed. The<br />
individual fields of the Node Descriptor are<br />
described in section 2.3.2.3 of the ZigBee<br />
specification.<br />
As with all unicasts after successful transmission<br />
the sequence number of the unicast is stated using<br />
the “SEQ:XX” prompt. When acknowledged (or<br />
not) the accompanying “ACK:XX” (or “NACK:XX”)<br />
prompt is displayed.<br />
SW release R302 ●<br />
©2012 Telegesis (UK) Ltd - 25 - <strong>AT</strong> <strong>Command</strong> <strong>Manual</strong> (Rev 3.08)