<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />
S1A – Input Buffer of I/O Port<br />
Description<br />
The Logical Levels at the I/O Pins<br />
Operations<br />
R LOCAL<br />
R REMOTE<br />
Becomes effective<br />
Instantly<br />
Storage<br />
Instant Reading of Port Status<br />
Range<br />
0000 to FFFF (ETRX2)<br />
00000000 to FFFFFFFF (ETRX3)<br />
ETRX2: representing I/O pins<br />
xxxx BA98 7654 3210<br />
ETRX3: representing the I/O pins<br />
xxxxxxxx <br />
S1A represents the logic level at each pin of the<br />
I/O port.<br />
Factory Default<br />
n/a<br />
SW release R300 ●<br />
S1B – PWM Pin Top Value<br />
Description<br />
The mode of operation for the special<br />
function pin<br />
Operations<br />
R/W LOCAL<br />
R/W REMOTE<br />
Operations<br />
Instantly<br />
Parameters<br />
XXXX<br />
Range<br />
0000 to FFFF<br />
This register represents the top value of the 16-bit<br />
counter counting from 0 to top repeatedly<br />
incrementing at 12MHz. When reaching top I/O3<br />
(ETRX2) or PB7 (ETRX357) is set, given that the<br />
PWM is enabled in S11.<br />
Storage<br />
Volatile<br />
Factory Default<br />
Defined in S1C<br />
SW release R300 ●<br />
©2012 Telegesis (UK) Ltd - 73 - <strong>AT</strong> <strong>Command</strong> <strong>Manual</strong> (Rev 3.08)