<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />
S1C – Initial value of S1B<br />
Description<br />
The initial setting of S1B stored in non<br />
volatile memory<br />
Parameters<br />
XXXX<br />
Operations<br />
R/W LOCAL<br />
R/W REMOTE<br />
Where XXXX represents the initial value of S1B<br />
which is loaded after boot-up, soft or hard reset.<br />
Becomes effective<br />
After Soft or Hard Reset<br />
Storage<br />
Factory Default<br />
Non-Volatile<br />
3A98 (800Hz 50% m/s ratio)<br />
SW release R300 ●<br />
S1D – PWM Pin Compare Value<br />
Description<br />
The mode of operation for the special<br />
function pin<br />
Operations<br />
R/W LOCAL<br />
R/W REMOTE<br />
Becomes effective<br />
Instantly<br />
Storage<br />
Volatile<br />
Parameters<br />
XXXX<br />
Range<br />
0000 to FFFF<br />
If the special function pin is enabled by setting bit F<br />
of S11, this register represents the compare value<br />
of the 16-bit counter counting from 0 to top<br />
repeatedly incrementing at 12MHz. When<br />
reaching compare I/O3 (ETRX2) or PB7<br />
(ETRX357) is cleared.<br />
Factory Default<br />
Defined in S1E<br />
SW release R300 ●<br />
S1E – Initial Value S1D<br />
Description<br />
The initial setting of S1D stored in non<br />
volatile memory<br />
Parameters<br />
XXXX<br />
Operations<br />
R/W LOCAL<br />
R/W REMOTE<br />
Where XXXX represents the initial value of S1D<br />
which is loaded after boot-up, soft or hard reset.<br />
Becomes effective<br />
After Soft or Hard Reset<br />
Storage<br />
Factory Default<br />
Non-Volatile<br />
1D4C (800Hz 50% m/s ratio)<br />
SW release R300 ●<br />
©2012 Telegesis (UK) Ltd - 74 - <strong>AT</strong> <strong>Command</strong> <strong>Manual</strong> (Rev 3.08)