<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />

S0F – Prompt Enable 2<br />

Description<br />

Defines the behaviour of the Device.<br />

Operations<br />

R/W LOCAL<br />

R/W REMOTE<br />

Becomes effective<br />

Instantly<br />

Notes<br />

Use of bit 8 requires bit 1 to be unset<br />

Parameters<br />

XXXX<br />

Where XXXX represents a 16-bit hexadecimal<br />

number.<br />

Range<br />

0000 to FFFF<br />

Bit F: Add prefix to local S-register reads<br />

(ETRX35n only)<br />

Bit E: Show RSSI and LQI for all received unicasts<br />

and broadcasts (ETRX35n only)<br />

Bit 9 – Bit D: Reserved<br />

Storage<br />

Non-Volatile<br />

Bit 8: Set: Show unhandled messages received<br />

by Endpoints 3 and above<br />

Bit 7: Set: Hide “AddrResp” prompt<br />

Bit 6: Set: Hide Network Manager Warning<br />

Bit 5: Set: Hide “DataMODE” prompt<br />

Bit 4: Set: Hide “CLOSED” prompt<br />

Bit 3: Set: Hide “OPEN” prompt<br />

Bit 2: Set: Hide all Sink Advertisements<br />

Unset: Show all Sink Advertisements,<br />

except advertisements by the current sink<br />

Bit 1: Set: Disable showing unhandled messages<br />

received by Endpoints 0, 2, 3 etc<br />

Bit 0: Set: Disable COO, FFD, SED and MED<br />

prompts<br />

Factory Default<br />