R308 AT Command Manual - wless.ru
R308 AT Command Manual - wless.ru
R308 AT Command Manual - wless.ru
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />
S0F – Prompt Enable 2<br />
Description<br />
Defines the behaviour of the Device.<br />
Operations<br />
R/W LOCAL<br />
R/W REMOTE<br />
Becomes effective<br />
Instantly<br />
Notes<br />
Use of bit 8 requires bit 1 to be unset<br />
Parameters<br />
XXXX<br />
Where XXXX represents a 16-bit hexadecimal<br />
number.<br />
Range<br />
0000 to FFFF<br />
Bit F: Add prefix to local S-register reads<br />
(ETRX35n only)<br />
Bit E: Show RSSI and LQI for all received unicasts<br />
and broadcasts (ETRX35n only)<br />
Bit 9 – Bit D: Reserved<br />
Storage<br />
Non-Volatile<br />
Bit 8: Set: Show unhandled messages received<br />
by Endpoints 3 and above<br />
Bit 7: Set: Hide “AddrResp” prompt<br />
Bit 6: Set: Hide Network Manager Warning<br />
Bit 5: Set: Hide “DataMODE” prompt<br />
Bit 4: Set: Hide “CLOSED” prompt<br />
Bit 3: Set: Hide “OPEN” prompt<br />
Bit 2: Set: Hide all Sink Advertisements<br />
Unset: Show all Sink Advertisements,<br />
except advertisements by the current sink<br />
Bit 1: Set: Disable showing unhandled messages<br />
received by Endpoints 0, 2, 3 etc<br />
Bit 0: Set: Disable COO, FFD, SED and MED<br />
prompts<br />
Factory Default<br />
0006<br />
SW release R301 ●<br />
©2012 Telegesis (UK) Ltd - 64 - <strong>AT</strong> <strong>Command</strong> <strong>Manual</strong> (Rev 3.08)