<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />
S21 – A/D3 Reading (ETRX3 series ADC2)<br />
Description<br />
The analogue reading of A/D3 (ETRX3<br />
series ADC2)<br />
ETRX2: Only when bit C of S11 is set, invalid<br />
otherwise<br />
ETRX3: Only when bit 15 (0x0F) of S15 is<br />
set, invalid otherwise<br />
Operations<br />
R LOCAL<br />
R REMOTE<br />
Becomes effective<br />
Instantly<br />
Storage<br />
Parameters<br />
XXXX<br />
Representation<br />
The hexadecimal reading of the analogue input in<br />
mV (mV * 10 on the ETRX3) with respect to<br />
ground. The return value will be undefined in case<br />
the corresponding A/D converter has not been<br />
enabled.<br />
Range<br />
ETRX2: 0000 – 04B0 (0 – 1200)<br />
ETRX3: 0000 – 2EE0 (0 – 12000)<br />
Instant Reading of analogue input<br />
SW release R300 ●<br />
S22 – A/D4 Reading (ETRX3 series ADC3)<br />
Description<br />
The analogue reading of A/D4 (ETRX3<br />
series ADC3)<br />
ETRX2: Only when bit B of S11 is set, invalid<br />
otherwise<br />
ETRX3: Only when bit 17 (0x11) of S15 is<br />
set, invalid otherwise<br />
Operations<br />
R LOCAL<br />
R REMOTE<br />
Becomes effective<br />
Instantly<br />
Storage<br />
Parameters<br />
XXXX<br />
Representation<br />
The hexadecimal reading of the analogue input in<br />
mV (mV * 10 on the ETRX3) with respect to<br />
ground. The return value will be undefined in case<br />
the corresponding A/D converter has not been<br />
enabled.<br />
Range<br />
ETRX2: 0000 – 04B0 (0 – 1200)<br />
ETRX3: 0000 – 2EE0 (0 – 12000)<br />
Instant Reading of analogue input<br />
SW release R300 ●<br />