R308 AT Command Manual - wless.ru
R308 AT Command Manual - wless.ru
R308 AT Command Manual - wless.ru
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />
S2F –Timer/Counter 3<br />
Description<br />
A multipurpose Timer/Counter whose<br />
functionality is defined by S30<br />
Operations<br />
R/W LOCAL<br />
R/W REMOTE<br />
Becomes effective<br />
Instantly<br />
Parameters<br />
XXXX<br />
A 16-bit hexadecimal number representing a<br />
threshold for either a timer or counter event to be<br />
triggered. When reading this register the threshold<br />
rather than the actual timer/counter value is<br />
displayed.<br />
If set to 0 the corresponding functionality is<br />
disabled.<br />
Storage<br />
Non-Volatile<br />
Factory Default<br />
00F2 (1min interval)<br />
SW release R300 ●<br />
S30 – Functionality For Timer/Counter 3<br />
Description<br />
Defines the functionality for Timer/Counter 3<br />
events.<br />
Operations<br />
R/W LOCAL<br />
R/W REMOTE<br />
Parameters<br />
XXXX<br />
If set to 0 the functionality is disabled. Please see<br />
section 0 for a list of the functionalities.<br />
Becomes effective<br />
Instantly<br />
Storage<br />
Non-Volatile<br />
Factory Default<br />
8015 (if not part of a network do <strong>AT</strong>+JN)<br />
SW release R300 ●<br />
©2012 Telegesis (UK) Ltd - 84 - <strong>AT</strong> <strong>Command</strong> <strong>Manual</strong> (Rev 3.08)