<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />

S27 – Functionality at Bootup<br />

Description<br />

Describes the immediate action taken after<br />

boot-up (and stack initialization).<br />

Operations<br />

R/W LOCAL<br />

R/W REMOTE<br />

Parameters<br />

XXXX<br />

If set to 0 the functionality is disabled. Please see<br />

section 0 for a list of available functionalities.<br />

Becomes effective<br />

Instantly<br />

Note<br />

On versions before R305 this was executed<br />

before the protocol stack was <strong>ru</strong>nning so it<br />

could not be used for network or message<br />

functions<br />

Storage<br />

Non-Volatile<br />

Factory Default<br />

0000 (none)<br />

SW release R305 ●<br />

S28 – Functionality at Network Join<br />

Description<br />

Describes the immediate action taken after<br />

joining a network.<br />

Operations<br />

R/W LOCAL<br />

R/W REMOTE<br />

Parameters<br />

XXXX<br />

If set to 0 the functionality is disabled. Please see<br />

section 0 for a list of available functionalities.<br />

Becomes effective<br />

Instantly<br />

Storage<br />

Factory Default<br />

Non-Volatile<br />

0000 (none)<br />

SW release R302 ●<br />

©2012 Telegesis (UK) Ltd - 80 - <strong>AT</strong> <strong>Command</strong> <strong>Manual</strong> (Rev 3.08)