<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />

S4A – Endpoint 2 Device Version<br />

Description<br />

Register defining the version of the device<br />

attached to the Node‟s endpoint 2<br />

Operations<br />

R/W LOCAL<br />

R/W REMOTE<br />

Parameters<br />

00XX<br />

The 8 bit version trailed by two leading 0‟s..<br />

Becomes effective<br />

Instantly<br />

Storage<br />

Non-Volatile<br />

Factory Default<br />

0000<br />

SW release R302 ●<br />

S4B – Endpoint 2 Input Cluster List<br />

Description<br />

Register defining the input cluster list of the<br />

device attached to the Node‟s endpoint 2<br />

Operations<br />

R/W LOCAL<br />

R/W REMOTE<br />

Becomes effective<br />

Instantly<br />

Parameters<br />

[XXXX,XXXX,XXXX,XXXX,XXXX,XXXX,<br />

XXXX,XXXX,XXXX,XXXX,XXXX,XXXX]<br />

A list of a maximum of 12 x 16 bit cluster IDs<br />

separated by commas. The list may have any<br />

length from 0 to 12 clusters<br />

Example<br />

<strong>AT</strong>S4B=1101,000D<br />

Storage<br />

Non-Volatile<br />

Factory Default<br />

0000<br />

SW release R302 ●<br />

©2012 Telegesis (UK) Ltd - 96 - <strong>AT</strong> <strong>Command</strong> <strong>Manual</strong> (Rev 3.08)