<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />
S-Register Overview (continued) Local R/W Remote R/W<br />
S27 Functionality 1 at Boot-up ( / ) ( / )<br />
S28 Functionality at Network Join ( / ) ( / )<br />
S29 Timer/Counter 0 ( / ) ( / )<br />
S2A Functionality for Timer/Counter 0 ( / ) ( / )<br />
S2B Timer/Counter 1 ( / ) ( / )<br />
S2C Functionality for Timer/Counter 1 ( / ) ( / )<br />
S2D Timer/Counter 2 ( / ) ( / )<br />
S2E Functionality for Timer/Counter 2 ( / ) ( / )<br />
S2F Timer/Counter 3 ( / ) ( / )<br />
S30 Functionality for Timer/Counter 3 ( / ) ( / )<br />
S31 Timer/Counter 4 ( / ) ( / )<br />
S32 Functionality for Timer/Counter 4 ( / ) ( / )<br />
S33 Timer/Counter 5 ( / ) ( / )<br />
S34 Functionality for Timer/Counter 5 ( / ) ( / )<br />
S35 Timer/Counter 6 ( / ) ( / )<br />
S36 Functionality for Timer/Counter 6 ( / ) ( / )<br />
S37 Timer/Counter 7 ( / ) ( / )<br />
S38 Functionality for Timer/Counter 7 ( / ) ( / )<br />
S39 Power mode (volatile) ( / ) ( / )<br />
S3A Initial Power Mode ( / ) ( / )<br />
S3B Start-up Functionality Plaintext A ( / ) ( / )<br />
S3C Start-up Functionality Plaintext B ( / ) ( / )<br />
S3D Supply Voltage ( /-) ( /-)<br />
S3E Multicast Table Entry 00 ( / ) ( / )<br />
S3F Multicast Table Entry 01 ( / ) ( / )<br />
S40 Source and Destination Endpoints for xCASTs (volatile) ( / ) ( / )<br />
S41 Initial Value of S40 ( / ) ( / )<br />
S42 Cluster ID for xCASTs (volatile) ( / ) ( / )<br />
S43 Initial Value of S42 ( / ) ( / )<br />
S44 Profile ID for xCASTs (volatile) ( / ) ( / )<br />
S45 Initial Value of S44 ( / ) ( / )<br />
S46 Start-up Functionality 32 bit number (volatile) ( / ) ( / )<br />
S47 Power Descriptor ( / ) ( / )<br />
S48 Endpoint 2 Profile ID ( / ) ( / )<br />
S49 Endpoint 2 Device ID ( / ) ( / )<br />
S4A Endpoint 2 Device Version ( / ) ( / )<br />
S4B Endpoint 2 Input Cluster List ( / ) ( / )<br />
S4C Endpoint 2 Output Cluster List ( / ) ( / )<br />
S4D Mobile End Device Poll Timeout ( / ) ( / )<br />
S4E End Device Poll Timeout ( / ) ( / )<br />
S4F MAC Timeout ( / ) ( / )<br />
Table 6: S-Register Overview<br />
©2012 Telegesis (UK) Ltd - 54 - <strong>AT</strong> <strong>Command</strong> <strong>Manual</strong> (Rev 3.08)