R308 AT Command Manual - wless.ru
R308 AT Command Manual - wless.ru
R308 AT Command Manual - wless.ru
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />
S14 – ETRX2: Pull-down enable ETRX3: Reserved<br />
Description<br />
Enables the built-in pull-downs for each<br />
individual I/O pin of the ETRX2.<br />
Operations<br />
R/W LOCAL<br />
R/W REMOTE<br />
Becomes effective<br />
After Reset<br />
Note<br />
To achieve ultra low current consumption it is<br />
recommended not to use the built-in pulldowns<br />
and leave this register in its default<br />
state.<br />
On the ETRX3 series this register is<br />
Reserved and currently not in use<br />
Storage<br />
Parameters<br />
XXXX<br />
Where XXXX represents a 16-bit hexadecimal<br />
number.<br />
Range<br />
0000 to FFFF<br />
representing I/O pins<br />
xx BA98 7654 3210<br />
e.g. setting bit 7 to 1 will enable the pull-down for<br />
I/O pin 7<br />
Factory Default<br />
0000<br />
Non-Volatile<br />
SW release R300 ●<br />
©2012 Telegesis (UK) Ltd - 69 - <strong>AT</strong> <strong>Command</strong> <strong>Manual</strong> (Rev 3.08)