<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />
S29 –Timer/Counter 0<br />
Description<br />
A multipurpose Timer/Counter whose<br />
functionality is defined by S2A<br />
Operations<br />
R/W LOCAL<br />
R/W REMOTE<br />
Becomes effective<br />
Instantly<br />
Parameters<br />
XXXX<br />
A 16-bit hexadecimal number representing a<br />
threshold for either a timer or counter event to be<br />
triggered. When reading this register the threshold<br />
rather than the actual timer/counter value is<br />
displayed.<br />
If set to 0 the corresponding functionality is<br />
disabled.<br />
Storage<br />
Non-Volatile<br />
Factory Default<br />
0004 (1s interval)<br />
SW release R300 ●<br />
S2A – Functionality For Timer/Counter 0<br />
Description<br />
Defines the functionality for Timer/Counter 0<br />
events.<br />
Operations<br />
R/W LOCAL<br />
R/W REMOTE<br />
Parameters<br />
XXXX<br />
If set to 0 the functionality is disabled. Please see<br />
section 0 for a list of the functionalities.<br />
Becomes effective<br />
Instantly<br />
Storage<br />
Non-Volatile<br />
Factory Default<br />
8010 (end devices poll parent)<br />
SW release R300 ●<br />