R308 AT Command Manual - wless.ru
R308 AT Command Manual - wless.ru
R308 AT Command Manual - wless.ru
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>R308</strong> <strong>AT</strong> <strong>Command</strong>s<br />
S39 – Power Mode<br />
Description<br />
The current power mode of the module<br />
Operations<br />
R/W LOCAL<br />
R/W REMOTE<br />
Becomes effective<br />
Instantly<br />
Parameters<br />
XXXX<br />
Range<br />
0000 – 0003<br />
The module‟s power mode as described in<br />
section 0.<br />
Storage<br />
Volatile<br />
Factory Default<br />
Defined in S3A<br />
SW release R300 ●<br />
S3A – Initial Power Mode<br />
Description<br />
The module‟s power mode after start-up and<br />
reset.<br />
Operations<br />
R/W LOCAL<br />
R/W REMOTE<br />
Becomes effective<br />
After hard or soft reset<br />
Parameters<br />
XXXX<br />
Range<br />
0000 – 0003<br />
The module‟s power mode as described in<br />
section 0.<br />
Storage<br />
Non-Volatile<br />
Factory Default<br />
0000<br />
SW release R300 ●<br />
S3B – Start-up Functionality Plaintext A<br />
Description<br />
Contains Text which is used by some of the<br />
actions described in section 0.<br />
Parameters<br />
Up to 50 characters<br />
Operations<br />
R/W LOCAL<br />
R/W REMOTE<br />
Becomes effective<br />
Instantly<br />
Storage<br />
Non-Volatile<br />
Factory Default<br />
BUTTON3<br />
SW release R300 ●<br />
©2012 Telegesis (UK) Ltd - 89 - <strong>AT</strong> <strong>Command</strong> <strong>Manual</strong> (Rev 3.08)