F. Supplying Streams<br />

1. Place Pumpers at the hydrants (or other water source) sending water to pumpers at the<br />

fire.<br />

2. Use an adequate number or size of supply line laid between pumpers and from the<br />

Pumper at the fire to the heavy stream devices.<br />

3. Engineers must figure nozzle pressure and friction loss in order to pump effective<br />

streams.<br />

G. Positioning the Device:<br />

1. Fog nozzles must be positioned close to the fire building.<br />

2. Solid stream nozzles will perform better if they are positioned some distance from the<br />

building.<br />

3. Any heavy stream device must be positioned so that it hits the fire at an effective angle.<br />

H. Directing Heavy Streams:<br />

1. A heavy stream should be moved horizontally across the fire area it is covering. The<br />

stream should also be moved up and down so it reaches to the full depth of the fire area.<br />

2. If a stream is not effective, it may need to be moved. If moving does not help, the size of<br />

the stream should be increased or additional streams should be placed in service.<br />

I. Shut Down:<br />

Overhaul<br />

1. A heavy stream should be used only as long as fire, steam, or white smoke is visible in<br />

the area covered by the stream.<br />

2. As soon as the above conditions no longer exist, the heavy stream should be shut down.<br />

3. Hand lines may be used to mop up.<br />

A. Overhaul is a primary function of the Truck/Ladder Company. The Engine Company shall support<br />

the Truck/Ladder personnel by staffing hand lines.<br />

B. As Truck/Ladder personnel open the building and expose fires in concealed spaces, the Engine<br />

crew shall extinguish.<br />

C. To achieve the best results, both companies must work as a team, each performing their own tasks.<br />

D. If a Truck/Ladder Company is not available, Engine Company personnel must perform the work.<br />

E. Safety is of utmost importance.<br />

F. Full protective clothing and SCBA shall be worn during overhaul.<br />

Effective: June 1, 1997 Revised: 5/14/2009 Page | 190<br />