<strong>Cleveland</strong> <strong>Fire</strong> <strong>Department</strong><br />
Operations <strong>Manual</strong><br />
Protective Clothing and Protective Equipment<br />
A. The <strong>Cleveland</strong> <strong>Fire</strong> <strong>Department</strong> shall provide each member with the appropriate protective<br />
clothing and protective equipment to provide protection from the hazards of the work environment<br />
to which the member is or may be exposed. Such protective clothing and protective equipment<br />
shall be suitable for the tasks which the member is expected to perform in that environment.<br />
B. Protective clothing and protective equipment shall be used whenever the member is or may be<br />
exposed to the hazards for which it is provided in accordance with the procedure in the section<br />
“Safety-Protective Clothing”.<br />
C. Members shall be fully trained in the care, use, inspection, maintenance, and limitations of the<br />
protective clothing and protective equipment assigned to them or available for their use. Protective<br />
clothing and protective equipment shall be used and maintained in accordance with the<br />
manufacturers’ instructions and the maintenance and inspection program of the <strong>Cleveland</strong> <strong>Fire</strong><br />
<strong>Department</strong>.<br />
D. All members who may be engaged in or exposed to the hazards of structural firefighting shall be<br />
provided with both protective coats and protective trousers that meet the requirements of NFPA<br />
1971, Standards on Protective Clothing for Structural <strong>Fire</strong> Fighting. This gear will be subject to<br />
replacement every 5 years or upon failing inspection.<br />
E. All members who may be engaged in or exposed to the hazards of structural firefighting shall be<br />
provided with helmets that meet the requirements of NFPA 1972, Standard on Structural <strong>Fire</strong><br />
Fighter’s Helmets.<br />
F. All members who may be engaged in or exposed to the hazards of structural firefighting shall<br />
provided with gloves that meet the requirements of NFPA 1973, Standard on Protective Gloves for<br />
Structural <strong>Fire</strong> Fighters.<br />
G. All members who may be engaged in or exposed to the hazards of structural firefighting shall be<br />
provided with footwear that meet the requirements of NFPA 1974, Standard on Protective<br />
Footwear for Structural <strong>Fire</strong> Fighters.<br />
H. All members who may be engaged in or exposed to the hazards of structural firefighting shall be<br />
provided with protective hoods that provide protection for the ears and neck and that interface<br />
with the SCBA face piece, protective coat, and helmet in accordance with Chapter 6 of NFPA<br />
1971, Standard on Protective Clothing for Structural <strong>Fire</strong> Fighting.<br />
I. All personnel of the <strong>Cleveland</strong> <strong>Fire</strong> <strong>Department</strong> shall wear all the protective clothing specified<br />
above at all times when involved in or exposed to the hazards of structural firefighting.<br />
J. When station/work uniforms are worn by members who may be engaged in or exposed to the<br />
hazards of structural fire fighting, such station/work uniforms shall meet the requirements of the<br />
<strong>Cleveland</strong> <strong>Fire</strong> <strong>Department</strong>.<br />
K. SCBA shall be provided for, and shall be used by, all personnel in compliance with the <strong>Cleveland</strong><br />
<strong>Fire</strong> <strong>Department</strong> procedure in the section “Safety-SCBA”.<br />
L. SCBA shall meet the requirements of NFPA 1981, Standard on Self-Contained Breathing<br />
Apparatus for <strong>Fire</strong> Fighting.<br />
Effective: June 1, 1997 Revised: 5/14/2009 Page | 290<br />
Approved by: Chief Chuck Atchley