Electrical<br />

Battery Power Distribution:<br />

MAIN B/C<br />

DISABLE RELAY<br />

APU B/C<br />

DISABLE RELAY<br />

GS AC<br />

MAIN<br />

B/C<br />

G9<br />

MAIN BAT<br />

THERMO<br />

SWITCH<br />

AUTO<br />

OFF<br />

BAT<br />

APU<br />

B/C<br />

APU<br />

START<br />

RELAY<br />

APU BAT<br />

THERMO<br />

SWITCH<br />

AUTO<br />

OFF<br />

BAT<br />

MAIN<br />

STANDBY<br />

XFR RELAY<br />

MAIN BAT<br />

APU BAT<br />

REMOTE ON/OFF (GND=OFF)<br />

MAIN HOT BAT<br />

K1<br />

APU BAT<br />

XFR RELAY<br />

APU<br />

START K2<br />

RELAY<br />

J9<br />

APU HOT BAT<br />

A7<br />

APU BAT<br />

A6<br />

J8<br />

K5<br />

STATIC INV<br />

MAIN<br />

DC BUS 3<br />

G6<br />

E7<br />

E8<br />

E9<br />

BCU 1<br />

IRS DC L<br />

IRS DC C<br />

IRS DC R<br />

A25<br />

A<br />

MAIN STANDBY AC<br />

AC 3<br />

AUTO<br />

OFF BAT<br />

K3<br />

MAIN BAT<br />

K4<br />

J7<br />

MAIN BAT<br />

RELAY<br />

BAT XFR<br />

RELAY<br />

BAT SWITCH<br />

SINGLE TRU<br />

OPERATION<br />

RELAY<br />

B<br />

DC 3<br />

DC VOLTAGE<br />

SENSE<br />

RELAY<br />

B/C<br />

BAT SWITCH<br />

BCU<br />

GS AC<br />

IBVSU CAPT<br />

IRS DC<br />

SINGLE TRU<br />

STATIC INV<br />

XFR RELAY<br />

BATTERY CHARGER<br />

BATTERY SWITCH<br />

BUS CONTROL UNIT<br />

GROUND SERVICE BUS, AC (115V)<br />

INSTRUMENT BUS VOLTAGE SENSE UNIT OF CAPTAIN<br />

INERTIAL REFERENCE SYSTEM, DC POWER SUPPLY<br />

ONLY ONE TRANSFORMER RECTIFIER UNIT IN USE<br />

(REFERRING TO DC BUS 1, 2, 3, 4)<br />

STATIC INVERTER (28V DC TO 115V AC)<br />

TRANSFER RELAY<br />

CONTROLLED<br />

BY BCU 1 OR 2<br />

CLOSED IF SINGLE TRU<br />

DIODE<br />

BATTERY (28V)<br />

AUTO<br />

OFF BAT<br />

CONTROLLED<br />

BY IBVSU CAPT<br />

OPEN IF ON AC 1<br />

BUS WITH AC (115V)<br />

BUS WITH DC (28V)<br />

CIRCUIT BREAKER (CB) ON P6 PANEL<br />

AUTO<br />

OFF<br />

BAT<br />

SWITCH ELEMENT OF<br />

STANDBY POWER SELECTOR<br />

REMOTE CONTROL CIRCUIT BREAKER (RCCB), CONTROLLED ON P6<br />

DIAGRAM CONTINUATION; REFER TO PREVIOUS PAGE FOR CONNECTION<br />