Fuel System<br />

EICAS Messages:<br />

>FUEL AUX ()<br />

>FUEL IMBAL 1-4<br />

>FUEL IMBAL 2-3<br />

>FUEL IMBALANCE<br />

>FUEL JETT ()<br />

>FUEL LO STAB L<br />

>FUEL LO STAB R<br />

>FUEL LOW CTR ()<br />

FUEL OVRD () AFT<br />

FUEL OVRD () FWD<br />

PRESS<br />

LIGHT<br />

PRESS<br />

LIGHT<br />

PRESS<br />

LIGHT<br />

PRESS<br />

LIGHT<br />

PRESS<br />

LIGHT<br />

PRESS<br />

LIGHT<br />

ADVISORY MESSAGES<br />

auxiliary tank transfer switch (L or R) is on<br />

AND auxiliary tank quantity below 230 kg (500 lb)<br />

difference greater than 1360 kg (3000 lb) between<br />

main tanks 1 and 4<br />

[message disappears when difference decreases<br />

below 450 kg (1000 lb)]<br />

difference greater than 2720 kg (6000 lb) between<br />

main tanks 2 and 3<br />

[message disappears when difference decreases<br />

below 450 kg (1000 lb)]<br />

difference greater than 1360 kg (3000 lb) between<br />

inboard and outboard main tanks after reaching<br />

tank-to-engine condition<br />

[message disappears when difference decreases<br />

below 450 kg (1000 lb)]<br />

jettison system (A or B) inoperative<br />

left stabilizer tank pump switch on<br />

AND stabilizer tank at critical limit<br />

[critical limit is 3600 kg (8000 lb) when pitch is<br />

above 5°, else 1200 kg (2600 lb)]<br />

right stabilizer tank pump switch on<br />

AND stabilizer tank at critical limit<br />

[critical limit is 3600 kg (8000 lb) when pitch is<br />

above 5°, else 600 kg (1300 lb)]<br />

center tank pump (L or R) running<br />

AND center tank at critical limit<br />

[critical limit is 7700 kg (17000 lb) when on ground,<br />

else 3200 kg (7000 lb) when pitch is above 5°,<br />

else 1300 kg (3000 lb)]<br />

aft override pump (2 or 3) low pressure when<br />

commanded on OR pump switched off while main<br />

tank quantities not equal<br />

forward override pump (2 or 3) low pressure when<br />

commanded on OR pump switched off while main<br />

tank quantities not equal<br />

(continued next page)<br />

— Page 449 —<br />