Fire Protection<br />

Valve Test:<br />

The valve test is a function of the freighter system only.<br />

Test switch<br />

(FIRE/OVHT TEST switch if GE or PW engines are<br />

installed, else ENG/APU/CARGO switch.)<br />

The valve test is disabled when the aircraft is in flight.<br />

Push & hold<br />

(momentary action) Keep the test switch pressed for at<br />

least 20 seconds to initiate the valve test program. The<br />

program will check all main deck cargo shutoff valves<br />

and the pack dump valves. The valves are used when the<br />

main deck fire suppression system reconfigures the air<br />

conditioning and starts depressurizing the cabin.<br />

For valve test EICAS messages refer to the next page.<br />