Air Systems<br />

Air Conditioning Controls:<br />

Passenger zones temperature<br />

selector (not on freighter)<br />

AUTO Sets master temperature for<br />

all passenger zones. Range is<br />

18°C to 29°C (65°F to 85°F)<br />

from C to W. Temperatures<br />

are accordingly adjusted by a<br />

zone temperature controller.<br />

In cruise, and if system is not<br />

in backup mode, flight attendants<br />

can enter corrections by<br />

±6°C on cabin temperature<br />

panel at purser station. Range<br />

limits cannot be exceeded. (In<br />

simulator, flight attendant inputs<br />

are generated randomly.)<br />

ALTN Bypasses zone temperature<br />

controller and deactivates<br />

cabin temperature panel at<br />

purser station. Zone trim<br />

air valves remain in their<br />

last positions. Pack output<br />

temperature regulation aims<br />

at average cabin temperature<br />

of 24°C (75°F).<br />

Flight deck temperature selector<br />

AUTO Range is 18°C to 29°C (65°F to 85°F) from C<br />

to W. Temperature is accordingly adjusted by<br />

a zone temperature controller.<br />

MAN Flight deck trim air valve under manual control.<br />

Rotation from MAN to W, and holding<br />

selector in W, moves trim air valve toward<br />

open position to supply warmer air. Vice<br />

versa: MAN to C for cooler air.<br />

Lower aft cargo temperature<br />

selector (not on freighter)<br />

AUTO Range is 4°C to 27°C (39°F to<br />

81°F) from C to W. Temperature<br />

is accordingly adjusted by<br />

a zone temperature controller.<br />

MAN Aft cargo trim air valve under<br />

manual control. Rotation from<br />

MAN to W, and holding selector<br />

in W, moves trim air valve<br />

toward open position to supply<br />

warmer air. Vice versa: MAN<br />

to C for cooler air.<br />

Zone reset switch<br />

Push Resets zone temperature<br />

control logic<br />

unless fault still exists.<br />

Reopens master trim air<br />

valve if duct overheat is<br />

no longer present.<br />

SYS<br />

FAULT<br />

LIGHT<br />

Zone duct overheat or<br />

zone controller fault<br />

except for aft cargo<br />

zone, or master trim air<br />

valve failure, or trim air<br />

switch off.<br />

— Page 114 —<br />