10.07.2015 Views

PXR3 Instruction Manual - Coulton Instrumentation

PXR3 Instruction Manual - Coulton Instrumentation

PXR3 Instruction Manual - Coulton Instrumentation

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Safety Precaution● Before using the <strong>PXR3</strong>, read the “<strong>Instruction</strong> <strong>Manual</strong>” or consult with your local distributor or Fuji Electric for safetypurpose.● The uses and places for some of equipment described in this manual are limited. Some devices need regular inspections.Consult with your local distributor or Fuji Electric.● Only electricians should connect this equipment.● The contents of this manual have been prepared carefully. However, it should be noted that Fuji Electric is not responsiblefor any loss, including consequential damage from errors in writing or missing information.Before operating the <strong>PXR3</strong>, carefully read the safety precaution in the “<strong>Instruction</strong> <strong>Manual</strong>”.Over-temperature ProtectionAny control system design should take into account that any part of the system has the potential to fail.For temperature control systems, continued heating should be considered the most dangerous condition, and the machineshould be designed to automatically stop heating if unregulated due to the failure of the control unit or for any other reason.The following are the most likely causes of unwanted continued heating:1) Controller failure with heating output constantly on2) Disengagement of the temperature sensor from the system3) A short circuit in the thermocouple wiring4) A valve or switch contact point outside the system is locked to keep the heat switched on.In any application where physical injury or destruction of equipment might occur, we recommend the installation of independentsafety equipment, with a separate temperature sensor, to disable the heating circuit in case of overheating.The controller alarm signal is not designed to function as a protective measure in case of controller failure.[Note]Modbus is a trademark of Modicon.Ciltect is a trade mark of CI Technology.Consult on the <strong>PXR3</strong> with the following:Head office11-2 Osaki 1-chome, Sinagawa-ku, Tokyo,141-0032 Japanhttp://www.fujielectric.co.jpSales Div.International Sales Dept.No.1 , Fuji-machi, Hino-city, Tokyo,191-8502 JapanPhone : 81-42-585-6201,6202Fax : 81-42-585-6187http://www.fic-net.co.jpInformation in this catalog is subject to change without notice.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!