Parameterdisplay symbolParameter nameDescriptionSetting range and factorydefault setting (*)User’sset valueParametermask DSPReferencepage1st soaksegment timeSets the 1st soak segment time.0 to 99h59m (*: 0.00)dSP6-32462nd target SVSets the 2nd target SV of ramp-soakoperation.Within the SV limit. (*: 0%FS)dSP6-64*462nd rampsegment timeSets the 2nd ramp segment time.0 to 99h59m (*: 0.00)dSP6-128462nd soaksegment timeSets the 2nd soak segment time.0 to 99h59m (*: 0.00)dSP7-1463rd target SVSets the 3rd target SV of ramp-soakoperation.Within the SV limit. (*: 0%FS)dSP7-2*463rd rampsegment timeSets the 3rd ramp segment time.0 to 99h59m (*: 0.00)dSP7-4463rd soaksegment timeSets the 3rd soak segment time.0 to 99h59m (*: 0.00)dSP7-8464th target SVSets the 4th target SV of ramp-soakoperation.Within the SV limit. (*: 0%FS)dSP7-16*464th rampsegment timeSets the 4th ramp segment time.0 to 99h59m (*: 0.00)dSP7-32464th soaksegment timeSets the 4th soak segment time.0 to 99h59m (*: 0.00)dSP7-64465th targetSVSets the 5th target SV of ramp-soakoperation.Within the SV limit. (*: 0%FS)dSP7-128*465th rampsegment timeSets the 5th ramp segment time.0 to 99h59m (*: 0.00)dSP8-1465th soaksegment timeSets the 5th soak segment time.0 to 99h59m (*: 0.00)dSP8-2466th target SVSets the 6th target SV of ramp-soakoperation.Within the SV limit. (*: 0%FS)dSP8-4*466th rampsegment timeSets the 6th ramp segment time.0 to 99h59m (*: 0.00)dSP8-8466th soaksegment timeSets the 6th soak segment time.0 to 99h59m (*: 0.00)dSP8-16467th target SVSets the 7th target SV of ramp-soakoperation.Within the SV limit. (*: 0%FS)dSP8-32*467th rampsegment timeSets the 7th ramp segment time.0 to 99h59m (*: 0.00)dSP8-64467th soaksegment timeSets the 7th soak segment time.0 to 99h59m (*: 0.00)dSP8-128468th targetSVSets the 8th target SV of ramp-soakoperation.Within the SV limit. (*: 0%FS)dSP9-1*468th rampsegment timeSets the 8th ramp segment time.0 to 99h59m (*: 0.00)dSP9-2468th soaksegment timeSets the 8th soak segment time.0 to 99h59m (*: 0.00)dSP9-446Ramp-soakmodeSelects the power-on start, repeat,and standby functions for rampsoakoperations.0 to 15 (*: 0)dSP9-846Note 1: When a customer does not specify the settings while ordering, the following settings are selected as factory defaults.Thermocouple input: Thermocouple K Measured range: 0 to 400°CResistance bulb input: Measured range: 0 to 150°CVoltage/Current input: Scaling: 0 to 100%8

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!