11.07.2015 Views

NetEx EFT213 Reference Manual Rel 5.4

NetEx EFT213 Reference Manual Rel 5.4

NetEx EFT213 Reference Manual Rel 5.4

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MUX-4015 Incompatible <strong>NetEx</strong>/eFT version for file transferSeverity: ErrorExplanation: The version of <strong>NetEx</strong>/eFT on the host you are currently connected to does not supportfile transfer with an z/OS host. File transfer cannot be accomplished unless a more recent version of<strong>NetEx</strong>/eFT is installed on the connected host.MUX-4016 Invalid code table length NNNSeverity: ErrorExplanation: When <strong>NetEx</strong>/eFT attempted to obtain the NETEX code conversion table, the tablelength returned was not 256 bytes. Correct the NETEX or hardware problem and retry the command.MUX-4017 Unsupported request code ‘SSS’ - no action takenSeverity: ErrorExplanation: The Multiplex Server detected an unsupported request code. Retry the command andif the problem persists, you may need to contact your site administrator to report and correct the problem.MUX-4018 Failed to invoke helper SSSSeverity: FatalExplanation: The Multiplex Server issued the TSO/E CALL command to invoke the Helper program,but initial communication could not be established. Verify the Helper program name is correctin the Multiplex Server execution parameters, and retry the command.MUX-4019 Timeout during helper initializationSeverity: FatalExplanation: The Multiplex Server issued the TSO/E CALL command to invoke the Helper programand initial communication was established, but the Helper program did not complete communicationswithin two minutes. This can sometimes occur on a very busy z/OS system. Retry the commandand if the problem persists, you may need to contact your site administrator to report and correctthe problem.MUX-4020 No client support for remote INPUT requestSeverity: ErrorExplanation: The client program does not support remote interactive commands. The remote commandcan be retried if enough information is supplied on the command line to cause the command tobecome noninteractive.MUX-4021 Server RESULTS failed (type=SSS status=NNN)Severity: ErrorExplanation: An error was detected during <strong>NetEx</strong>/eFT server processing. Retry the command and ifthe problem persists, you may need to contact your site administrator to report and correct the problem.MUX213-8001 Missing APPL_IDSeverity: ErrorExplanation: The TSO/E (TCAS) application name is missing in the Multiplex Server execution parameters.Correct the problem and restart the Multiplex Server.MUX213-8002 All connections to TSO are busySeverity: ErrorExplanation: The number of remote <strong>NetEx</strong>/eFT sessions to TSO/E is already at the maximum allowed.Retry the command at a later time.REF-eFT213-R<strong>5.4</strong>-08 Appendix B. <strong>NetEx</strong>/eFT Error Messages for IBM z/OS Page 239

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!