MUX213-8003 Could not find PROCESS: SSSSeverity: ErrorExplanation: An error was detected during Multiplex Server login processing. Verify the TSO/Eapplication name is the same in both the Multiplex Server execution parameters and the MultiplexServer ACF/VTAM configuration parameters. Correct the problem and restart the Multiplex Server.MUX213-8004 Login exceeded NNN second timeoutSeverity: ErrorExplanation: TSO/E logon processing exceeded the maximum time allowed. This can be caused byan undetected TSO/E input prompt during logon or can sometimes occur on a very busy z/OS system.If the system is busy, specify a larger value for the LOGTIMEOUT keyword in the Multiplex Serverexecution parameters and restart the Multiplex Server. Correct the problem and retry the command.MUX213-8005 Missing USERNAMESeverity: ErrorExplanation: The TSO/E logon cannot complete because no user name (TSO/E user ID) was suppliedon the CONNECT command or defaulted in the Multiplex Server execution parameters. Retrythe command with a valid user name.MUX213-8006 No response supplied to a LOGIN promptSeverity: ErrorExplanation: A TSO/E input prompt was detected during TSO/E logon processing. No response tothe prompt was supplied on the CONNECT command or in the Multiplex Server execution parameters.Retry the command supplying a response to the prompt.MUX213-8008 Failed to connect to TSOSeverity: ErrorExplanation: TSO/E disconnected before logon could be completed. Verify the ACF/VTAMLOGMODE parameter is correct in the Multiplex Server ACF/VTAM configuration parameters.Correct the problem and restart the Multiplex Server.MUX213-8011 Failed to execute command: SSSSeverity: ErrorExplanation: The Multiplex Server could not pass a line of input to TSO/E. Retry the command andif the problem persists, you may need to contact your site administrator to report and correct the problem.MUX213-8012 VTAM connection lostSeverity: FatalExplanation: The ACF/VTAM connection between the Multiplex Server and TSO/E has been lost.The <strong>NetEx</strong>/eFT session is disconnected. This can sometimes occur if the TSO/E user has been terminatedafter there has been no TSO/E activity for an extended period of time. Issue a new CONNECTcommand to reestablish the connection.Page 240 Appendix B. <strong>NetEx</strong>/eFT Error Messages for IBM z/OS REF-eFT213-R<strong>5.4</strong>-08

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!