12.07.2015 Views

ISDN Protocol Administrator's and Developer's Guide ... - Intervoice

ISDN Protocol Administrator's and Developer's Guide ... - Intervoice

ISDN Protocol Administrator's and Developer's Guide ... - Intervoice

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

T303Starts upon the sending of a Setup message. This timer is stoppedupon receipt of a Alert, Connect, Setup Acknowledge, CallProceeding or Release Complete message. If this timer expires,another Setup message is sent <strong>and</strong> the T303 timer is restarted. Ifthere is no response to the second Setup message <strong>and</strong> the timerexpires for the second time, a Release Complete message is sent <strong>and</strong>the call is returned to the Idle state. The range is 1 to 600 seconds.T304Starts upon the sending of an Information message in Overlapsending. The Information message contains part or all of a CalledParty number. This timer is stopped upon receiving a CallProceeding, Alert, Connect or Disconnect message. If this timerexpires, a Disconnect message is sent. The range is 1 to 600 seconds.T305Starts upon the sending of a Disconnect message. This timer isstopped upon receipt of a Release or Disconnect message. If thistimer expires, a Release message is sent. The range is 1 to 600seconds.T308Starts upon the sending of a Release message. This timer is stoppedupon receipt of a Release Complete or Release message. If this timerexpires, another Release message is sent, <strong>and</strong> the T308 timer isrestarted. If the T308 timer expires a second time, the B channel isplaced into Maintenance Condition. The range is 1 to 600 seconds.T309Starts if the Data Link is disconnected. If the Data Link isreconnected, this timer is stopped. If the timer expires, internalconnections are cleared <strong>and</strong> B channels are released. The range is 1to 600 seconds.T310Starts upon the receipt of a Call Proceeding message. The timer isstopped if an Alert Connect, Disconnect or Progress message isreceived. If this timer expires, a Disconnect message is sent. Therange is 1 to 600 seconds.T313Starts following the sending of a Connect message. This timer isstopped upon receipt of a Connect Acknowledge message. If thistimer expires, a Disconnect message is sent. The range is 1 to 600seconds.14-8 <strong>ISDN</strong> <strong>Protocol</strong> Administrator’s <strong>and</strong> Developer’s <strong>Guide</strong> 60001262, First Edition

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!