(continued)<br />

Is Fuel Available<br />

> (4 x FC4) ?<br />

No<br />

Is Fuel Available<br />

> (3 x FC4) ?<br />

No<br />

Is Fuel Available<br />

> (2 x FC4) ?<br />

No<br />

Is Fuel Available<br />

> FC4 ?<br />

N = 1<br />

PL = 100%<br />

No engines ON<br />

No<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

No<br />

F = Fuel Available / 5<br />

Engines 1,2,3,4,5 ON<br />

N = 5<br />

F = Fuel Available / 4<br />

Engines 1,2,3,4 ON<br />

N = 4<br />

F = Fuel Available / 3<br />

Engines 1,2,3 ON<br />

N = 3<br />

F = Fuel Available / 2<br />

Engines 1 ,2 ON<br />

N = 2<br />

F = Fuel Available<br />

Engine 1 ON<br />

N =1<br />

Does N<br />

= 2 ?<br />

Yes<br />

PL = 100%<br />

Engine 1 ON<br />

No<br />

Does N<br />

= 3 ?<br />

Yes<br />

PL = 100%<br />

Engines 1 ,2 ON<br />

Re-calculate SFC and<br />

Ratio using Figures<br />

5.10 and 5 .12<br />

145<br />

Is F = FC1 ?<br />

No<br />

Is F = FC2 ?<br />

No<br />

Is F = FC3 ?<br />

No<br />

Is F = FC4 ?<br />

No<br />

Is F < FC1 ?<br />

No<br />

Is FC1 < F < FC2 ?<br />

No<br />

Is FC2 < F < FC3 ?<br />

No<br />

No<br />

FC3 < F < FC4<br />

Power = PL x Rated Power / 100<br />

Elec = Power x Engines x Gen x PF / 1 00<br />

Heat = Ratio x Elec<br />

Does N<br />

= 4 ?<br />

Yes<br />

PL = 100%<br />

Engines 1 ,2,3 ON<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

No<br />

PL = PC1<br />

PL = PC2<br />

PL = PC3<br />

PL = PC4<br />

PL = ((( FC1 - F ) / FC1 )<br />

x ( PC1 - PC2 )) + PC1<br />

PL = ((( F - FC1 ) / ( FC2 - FC1 ))<br />

x ( PC2 - PC1 )) + PC1<br />

PL = ((( F - FC2 ) / ( FC3 - FC2 ))<br />

x ( PC3 - PC2 )) + PC2<br />

PL = ((( F - FC3 ) / ( FC4 - FC3 ))<br />

x ( PC4 - PC3 )) + PC3<br />

Does N<br />

= 5 ?<br />

Yes<br />

PL = 100%<br />

Engines 1,2,3,4 ON<br />

Figure 5.14 (cont) Fuel Consumption and Possible Load Determination<br />

(Efficiency)<br />

Yes<br />

Is PL <<br />

Min ?<br />

After either process to find the possible percentage load with the fuel available,<br />

this should be checked to see if it is below the minimum load, and, if not, the<br />

specific fuel consumption and heat to electricity ratio should be recalculated as<br />

before.<br />