Is Min = 0 ?<br />

No<br />

Is Min = PC1<br />

?<br />

No<br />

Is Min = PC2<br />

?<br />

No<br />

Is Min = PC3<br />

?<br />

No<br />

Is Min = 100 %<br />

?<br />

No<br />

Is Min < PC1<br />

?<br />

No<br />

Is PC1 < Min < PC2 ?<br />

No<br />

Is PC2 < Min < PC3 ?<br />

No<br />

PC3 < Min < PC4<br />

Is BesEff <<br />

MinEff ?<br />

Yes<br />

BestEff = MinEff<br />

BestPL = Min<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

MinEff = 0<br />

MinEff = Eff1<br />

MinEff = Eff2<br />

MinEff = Eff3<br />

MinEff = Eff4<br />

Eff = Electrical Efficiency (% )<br />

Min = Minimum Load (% )<br />

MinEff = Efficiency at Minimum Load (% )<br />

BestEff = Optimum Efficiency Level (% )<br />

BestPL = Optimum Percentage Load (% )<br />

Req = Required Power (kW)<br />

PC1 = 25 % or other input percentage<br />

PC2 = 50 % or other input percentage<br />

PC3 = 75 % or other input percentage<br />

Eff1 = Eff at PC1<br />

Eff2 = Eff at PC2<br />

Eff3 = Eff at PC3<br />

Eff4 = Eff at 1 00 %<br />

MinEff = ((PC1 - Min) / PC1 )) x (Eff1 - Eff2) + Eff1<br />

MinEff = ((Min - PC1) / (PC2 - PC1)) x (Eff2 - Eff1) + Eff1<br />

MinEff = ((Min - PC2) / (PC3 - PC2)) x (Eff3 - Eff2) + Eff2<br />

MinEff = ((Min - PC3) / (PC4 - PC3)) x (Eff4 - Eff3) + Eff3<br />

Is BesEff < Eff1<br />

Is BesEff < Eff2<br />

No No No<br />

and PC1 > Min ?<br />

and PC2 > Min ?<br />

Best Eff = Eff1<br />

BestPL = PC1<br />

BestEff = Eff2<br />

BestPL = PC2<br />

155<br />

Is BesEff < Eff3<br />

and PC3 > Min ?<br />

Yes Yes<br />

Yes<br />

BestPower = BestPL x Rated Power / 100 Factor = Req / BestPower<br />

(continued)<br />

BestEff = Eff3<br />

BestPL = PC3<br />

Figure 5.19 Determination <strong>of</strong> Percentage Load for a Fuel Cell<br />

Best Eff = Eff4<br />

BestPL = 100