2842_LVIA<br />

10<br />

September 2011<br />

GALLOPER WIND FARM SUBSTATION<br />

h) Figures 2890/PM_AM/01B/YR15, 2890/PM_AM/04B/YR15,<br />

2890/PM_AM/05B/YR15<br />

1.3.11. Photomontage views at Year 15 (when proposed planting will have<br />

matured) from Viewpoints 1, 4 and 5 with the layout as shown in d)<br />

(i.e. with the potential 14m high building in the ‘worst case’ location<br />

for that particular viewpoint and with the ‘additional mitigation<br />

area’).<br />

1.3.12. Planting heights illustrated after 15 years are 5.1m for proposed<br />

woodland core (allowing for planting at 600mm height and average<br />

growth of 300mm per year) and 3m for woodland edge (allowing for<br />

planting at 600mm height and average growth of 200mm per year).<br />

1.3.13. It will be necessary to include a number of lightning rods within the<br />

development on buildings and other structures. These will have a<br />

height of up to 3m above these elements and a diameter of up to<br />

50mm. They are not included on the photomontages or on the<br />

wireframes showing the illustrative layout, as they will only be<br />

visible at close distances due to their small diameter. The potential<br />

envelope of the lightning rods is shown on wireframe Figures<br />

2890/WF-DE/01 to 2890/WF-DE/08 and their effects have been<br />

assessed in this LVIA.<br />

1.3.14. This LVIA has been undertaken on the assumption that buildings and<br />

equipment could potentially occupy the entire development<br />

envelopes, in order to give an indication of maximum potential<br />

effects. The judgements of effects have, therefore, been based on the<br />

wireframes noted in a) and e), with the screening effects of vegetation<br />

being judged with reference to photomontages noted in c), d), g) and<br />

h).<br />

1.3.15. The gantries and sealing end compounds will be limited to the<br />

equipment shown in the photomontages although there will be<br />

minor variations in their location and levels. Minor variations will<br />

not change the assessed effects.