The pitch <strong>of</strong> the machine is 1. The pitch factor for the fundamental component <strong>of</strong><br />

MMF c<strong>an</strong> be expressed as:<br />

k<br />

p1<br />

⎛ ⎞<br />

sin⎜<br />

W π<br />

= ⋅ ⎟<br />

⎜ 2 ⎟<br />

⎝τ<br />

p ⎠<br />

⎛ π ⎞<br />

= sin⎜1⋅<br />

⎟ = 1<br />

⎝ 2 ⎠<br />

B) Distribution factor k d1<br />

64<br />

(2.56)<br />

Assume the phase belt is 60 o . Then the slots per phase belt will be 6 in this machine.<br />

The phase belt in per unit <strong>of</strong> a pole pitch c<strong>an</strong> be expressed by taking the appropriate ratio<br />

<strong>of</strong> slots.<br />

Z<br />

τ<br />

p<br />

6 1<br />

= =<br />

18 3<br />

Hence from Table 2.1 the distribution factor is:<br />

(2.57)<br />

k 0.<br />

966<br />

(2.58)<br />

d1<br />

=<br />

C) Slot opening factor k χ1<br />

The slot opening factor is determined from:<br />

( χ 2)<br />

sin<br />

k χ 1 =<br />

(2.59)<br />

χ 2<br />

bos<br />

where, χ = π = 0.<br />

0742 .<br />

τ<br />

Therefore,<br />

p<br />

( 0.<br />

0371)<br />

sin<br />

k χ1<br />

=<br />

= 0.<br />

9991<br />

(2.60)<br />

0.<br />

0371<br />

D) Skew factor k<br />

s1