o<br />
307<br />
The solenoids in the valve block assembly do<br />
not function to shift the venting valve or<br />
the power failure valve.<br />
Remove the inspection cover from the<br />
solenoid housing and examine the solenoids<br />
to see if, they operate to shift<br />
the venting valve, when the starting<br />
handle is moved to the ItStart It position.<br />
Also check to see that the power failure<br />
valve shifts whenthe electric motor is<br />
turned <strong>of</strong>f and on.<br />
(4) The venting valve or the power failure valve<br />
stuck.<br />
Operate the valves manually by moving<br />
their operating levers_ inside <strong>of</strong> the<br />
solenoid housing to insure that no friction<br />
exists Lnthe valves, and the valve<br />
springs function .correctly.<br />
(5) The starting sv.itch fails to close or make<br />
contact.<br />
Remove the cover <strong>of</strong> the starting switch<br />
and check to see if the contacts close<br />
when the starting handle is moved to<br />
theltStartlt Position.<br />
(6) The loading and unloading position limit<br />
switches fail to close or make contacts.<br />
Remove the covers <strong>of</strong> the switches which<br />
are not held open by the powder car and<br />
check to see that the switches are<br />
closed, and the contacts in good condition.<br />
(7) The wiring maybe ruptured or a short circuit<br />
may exist.<br />
Check the wiring for rupture or short<br />
circuit.<br />
(b) Failure <strong>of</strong> control pump circuit. - If pressure<br />
builds up to operate the hoist with the control<br />
selector lever positioned for a nServo Mechanical"<br />
controlled cycle, but considerable effort<br />
is required to operate the hoist and lower control<br />
lever, the control pumphas failed. The<br />
trouble may be caused by one <strong>of</strong> the following<br />
reasons:-