317<br />

have been fitted individually over the dowel pins 196732-8.<br />

If a new solenoid is to be installed the solenoid case 274279-1<br />

is to be removed by first loosening the clamp bolts 196780-4<br />

in the solenoid operating levers 274273-3 and 274273 (see<br />

274272 valve block), then remove the levers. Next remove the<br />

14 solenoid housing mounting screws 196780-4 and the case<br />

274279-1 can be removed. Next remove the 196826-9 pipe plugs<br />

located on the back <strong>of</strong> the solenoid cases, and drive out the<br />

dowel pins 196732-8. The solenoid is to be mounted in place<br />

and secured with its mounting screws. Nowuse a 19/64 inch<br />

drill and with the dowel holes as a guide drill thru the solenoid<br />

mounting flanges. Care must be taken not to drill too<br />

deep and injure the solenoid coils. Ream the holes for the<br />

5/16 inch dowel pins 196732-8, and assemble the pins and the<br />

pipe plugs 196826-9. Remove the solenoid and reassemble the<br />

case 274279-1 to the val.ve block cover 274275-1. Reassemble<br />

the solenoid operating levers, and both solenoids. Connect<br />

the terminal wires and then replace the cover.<br />

113. To remove the air breather assembly (dr . no. 274286-2),<br />

Grab the lower hexagonal portion <strong>of</strong> the breather assembly with<br />

a wrench and screw the breather assembly out <strong>of</strong> the elbow<br />

206447-4·<br />

To dismant l e the air breather. - Grab one <strong>of</strong> the hexagonal<br />

portions <strong>of</strong> the breather in a vise, and screw<br />

<strong>of</strong>f the other cover with a wrench. Take precautions<br />

against losing the small needle valve when dismantling<br />

the assembly.<br />

114. To remove the control pump gear case assembly. -<br />

(Refer dr. no. 274247.) First disconnect the tubing from the<br />

#7 flange connections and disconnect and remove the coupling<br />

between the electric motor and the A-end shaft. Remove the<br />

14 screws 206829-5 and then insert three 3/8!l-16 jack screws<br />

in the 1/2 inch drilled holes and remove the assembly by turning<br />

the jack screws evenly. Care must be taken not to injure<br />

the oil seal 274338-7.<br />

115. To dismantle the control pump gear case assembly. -<br />

After the assembly has been removed from the A-end remove the<br />

two screws 180226-6 remaining in the cover 274295-1. Insert<br />

jack screws in the three 3/8"-16 tapped holes in the cover<br />

274295-1, and remove the cover by turning the jack screw evenly<br />

until the cover slides <strong>of</strong>f the dowel pins. The gear 274298-1<br />

can nowbe lifted out <strong>of</strong> the case. 274296-1 and the gear 274298-5<br />

can be removed from the drive shaft 274300-1.<br />

116. To reassemble the control pump gear case assembly. -<br />

Wash all parts in a non-acid cleaning solution. The assembled<br />

gear case can be reassembled to the A-end, however for ease