",<br />

231<br />

It is poss ible to assemble this pump for opposite<br />

hand rotation, and care should be taken upon reassembly,<br />

to check the rotation. In this particular<br />

installation, the rotation is as indicated by the<br />

arrow on the A-end. It should be noted that there<br />

are arrows on both bushings and the rotor, and when<br />

properly assembled, all three <strong>of</strong> these arrows will<br />

point in the direction <strong>of</strong> the desired rotation. The<br />

vanes are assembled with" the chamfer on the trailing<br />

edge.<br />

When replacing pump head 220648-8, care should be<br />

taken to tighten screws that are diametrically opposi<br />

te. It is good practice to turn the shaft while<br />

these screws are being tightened to insure that the<br />

rotor is not binding.<br />

60. Reassemb ly. - It is essential before reassembly that<br />

all parts are carefully washed in a non-acid cleaning fluid<br />

to insure absolute cleanliness.<br />

Care should also be exercised upon reassembly not to injure<br />

oil seals.