199<br />

(a) Power plant and control devices.<br />

(1) Electric motor and controller.<br />

(2) A-end.<br />

(3) Auxiliary pump.<br />

(b) Hydraulic motor drive unit (B-end).<br />

(C) Couplings for connecting units.<br />

'Power Plant and Control Devices<br />

7. Electric motor. - The electric motor is a power<br />

unit <strong>of</strong> commercial design and manur acture (Louis Allis Co .).<br />

Details <strong>of</strong> the design and general arrangement <strong>of</strong> the assembly,<br />

wi th rotor shaft drive coupling provisions for the A-end and<br />

the auxiliary pump, are shown on drawing 231543. Type and<br />

performance data areas follows:<br />

Type: Squirrel cage induction; 440 volts; 60 cycle;<br />

3 phase; horizontal mounting; fan-cooled;<br />

waterpro<strong>of</strong> enclosure.<br />

H.P. - - - - - - - - - - 40 (overload rating, 72)<br />

Speed - - - - - - - - - - - - - - - - Constant<br />

R.P.M., full load - - - - - - - - - - - - 1160<br />

Amperes, full load - - - - - - - - - - - - - - 48<br />

Weight, pounds - - - - - - - - - 1200<br />

Manufacturers type designation RX-frame 445-S<br />

8. Controller. - The controllerisan across-the-line,<br />

magnetic motor starter, <strong>of</strong> shockpro<strong>of</strong> design, semiautomatic<br />

operation, waterpro<strong>of</strong> enclosure, arranged with an externally<br />

operated door interlock disconnect switch. It is an assembly<br />

<strong>of</strong> commercially manufactured parts (\.-lard Leonard Electric Co.)<br />

providing control and protection for the above described motor.<br />

With a master switch push-button station it is mounted on the<br />

circular bulkhead, in the machinery space, immediately forward<br />

<strong>of</strong> the power drive unit. The installation has arrangement <strong>of</strong><br />

the starting circuit, power circuit and protective devices as<br />

shown on the wiring diagram <strong>of</strong> drawing 231545. The protective<br />

features there indicated comprise undervoltage, short circuit<br />

and overload protection <strong>of</strong> the following types.<br />

(a) Short circuit protection. - Two mainline fuses,<br />

400 amperes, 250 volts, each, bridge two phases<br />

<strong>of</strong> the power circuit to provide motor short<br />

circuit protection.