.250<br />

(f) Before operating the hoist under projectile<br />

loads verify adequacy <strong>of</strong> rack paid and tube pawl<br />

lubrication.<br />

(g) Electric motor direction rotation. - If either<br />

power unit is new, or has been disassembled,<br />

or if any lead to either motor or controller<br />

has been discormected, it is imperative to<br />

verify the motor direction <strong>of</strong> rotation before<br />

operating. This is particularly importa:p.twith<br />

respect to the cradle operating motor as the<br />

two vane type pumps driven by that unit will<br />

be damaged if reversed.<br />

(h) Pressure tests. - Gauge checks should be performed<br />

quarterly to verify correct pressures<br />

in the pawl operating circuits.<br />

42. Hydrau l t c 0 t l . - The hydraulic oil to be used in<br />

both the main system and the cradle operating system is that<br />

specified in O.S. 1113. Whenreplacing or when replenishing<br />

oil pour through a fine meshwire strainer <strong>of</strong> at least 120 wires<br />

to the inch. Newassemblies should be drained after fLf teen<br />

hours operation and should then be thoroughly flushed clean<br />

and refilled with fresh oil or carefully salvaged oil. Perform<br />

test inspection and analysis <strong>of</strong> oil sample from each system<br />

monthly. If there 1S evidence <strong>of</strong> sludge, water or acidity,<br />

drain, flush and refill with fresh oil-. The amount <strong>of</strong> oil required<br />

to fill each cradle operating system (including the powder<br />

hoist upper door circuit) is 35 gallons. The system is<br />

self venting. The amount <strong>of</strong> oil required to fill the main hoist<br />

system is 25 gallons. This circuit requires venting at the<br />

needle valve in ·the upper cylinder head.<br />

43. BUffer fluid. - The liquid to be used in the cradle<br />

buffer is recoil cylinder liquid as specified in the latest<br />

revision <strong>of</strong> O.D. 1914.<br />

44. Lub r i c a t ion. - All projectile hoist assemblies must<br />

be lubricated with the lubricants and according to the frequencies<br />

specified on the lubrication chart.<br />

45. Bx er c i se checks. - Exercise each cradle operating<br />

assembly including the pawl control mechanisms at least once<br />

weekly. The operation must include check <strong>of</strong> response action<br />

to verify normal functioning <strong>of</strong> all control, indicatcr and pawl<br />

operating devices.<br />

46. Installation and<br />

overhauling or servicing the<br />

instructions <strong>of</strong> chapter XV.<br />

maintenance. - Wheninstalling,<br />

hydraulic units comply with the