221<br />
(i) Loose or broken operating line.<br />
Leaks in pressure lines are not likely<br />
to occur except in piping and may therefore<br />
be easily located by inspection <strong>of</strong><br />
external lines and those inside <strong>of</strong> A-end<br />
tank.<br />
(j) Scored valve plate in main pump or hydraulic<br />
motor.<br />
Inspect and check for foreign matter in<br />
system.<br />
(k) Broken or distorted auxiliary pump shaft.<br />
Inspect auxiliary pump.<br />
( Z) Excessive internal leakage in auxiliary pump.<br />
Pump head too loose. Screws should be<br />
tightened. Precautions should be taken<br />
not to clamp head too tightly as rotor<br />
must rotate freely when moved by hand.<br />
Check Lnt.er naL parts' for scoring by foreign<br />
matter.<br />
39. Failure to rotate. - If pressure is available in<br />
the system and the projectile ring will not operate it will<br />
probably be due to one <strong>of</strong> the following causes.<br />
(a) Insufficient pressure in operating lines.<br />
Lock output shaft and check setting <strong>of</strong><br />
main pump relief valves for 2200 Lbs . per<br />
sq. ~n. pressure.<br />
(b) Insufficient clearance between deceleration<br />
cams and link rollers.<br />
There must be approximately 3/64 H clearance<br />
between rollers and cams when unit<br />
is in latched position. This is to permit<br />
suffic ient <strong>of</strong>fset <strong>of</strong> pump yoke to<br />
overcome internal leakage and to start<br />
rotation.<br />
(C) Excessive internal leakage in main pumpor hydraulic<br />
motor.<br />
Manually drive proj ectile ring to midposi<br />
tion. Then turn power on and shift