Adjustments<br />

24. The hydraulic mechanisms have been factory adjusted<br />

to satisfactorily meet all operating conditions. If it is<br />

necessary to dismantle the equipment, adjustment must be made<br />

at reassembly as the work progresses. When disassembling, it<br />

is desirable to mark all mating parts such as cams, gears,<br />

linkages and adjustable pieces. The adjustments prescribed<br />

in the following paragraphs are given in the order <strong>of</strong> reassembly.<br />

25. Starting valve adjustment. - The starting valve<br />

must be adjusted before the valve block is mounted on the A-end<br />

case. The adjustment is located at point ITAITas indicated on<br />

figure 37. The clearance required is .005 inch between the<br />

shoulder <strong>of</strong> .t.he top land <strong>of</strong> the valve and the valve block<br />

mounting plate as shown on figure 38.<br />

With the valve held against shoulder by spring<br />

271702-11 and with the clevis roller held in the<br />

notch <strong>of</strong> the starting earn, measure the distance from<br />

the bottom <strong>of</strong> the clevis to the valve block mounting<br />

face. Adjust the valve to suit. For accuracy<br />

a depth gauge should be used in making the setting.<br />

Best performance <strong>of</strong> the assembly will be assured if<br />

this setting is maintained.<br />

ADJUST THIS SCREW ---'<br />

TO PROVIDE .005 INCH CLEARANCE<br />

HERE<br />

Fig. 38 - Starting Valve Adjustment