silent-time<br />

LINE COMMANDS<br />

Use this command to set the amount of time the management console is<br />

inaccessible after the number of unsuccessful logon attempts exceeds the<br />

threshold set by the password-thresh command. Use the no form to<br />

remove the silent time value.<br />

Syntax<br />

silent-time seconds<br />

no silent-time<br />

seconds - The number of seconds to disable console response.<br />

(Range: 0-65535; 0: no silent-time)<br />

Default Setting<br />

The default value is no silent-time.<br />

Command Mode<br />

Line Configuration<br />

Command Usage<br />

If the password threshold was not set with the password-thresh<br />

command, silent-time begins after the default value of three failed<br />

logon attempts.<br />

Example<br />

To set the silent time to 60 seconds, enter this command:<br />

Console(config-line)#silent-time 60<br />

Console(config-line)#<br />