AS-Interface Configuration<br />

Step Action<br />

6 Click on the Copy to project button.<br />

The Copy to project function allows you to copy a slave detected on the network<br />

to the project Device tree. You can select several slaves using SHIFT+click, then<br />

use the Copy to project button to copy all selected devices to the project Device<br />

tree. Slaves with the same address will be overwritten<br />

Your project is now updated with all connected slave devices under the Device<br />

tree. You need to download the application again to make these changes<br />

operational.<br />

7 If you want to add another AS-Interface slave, connect it to your Fieldbus and<br />

run a new scan (Step 3).<br />

Manually Add a Generic Slave Device<br />

If you want to <strong>manual</strong>ly configure your AS-Interface Slave device, you can add a<br />

generic AS-Interface Slave and configure its profile.<br />

This procedure is similar to the catalog method, but in this case you must choose a<br />

special device from the list.<br />

The procedure shows you how to add generic slave devices to your project:<br />

Step Action<br />

1 Go to the Program menu of SoMachine:<br />

106 EIO0000000384 04/2012