Serial Line Configuration<br />

Step Action<br />

2 Click the button New to create a new initialization value:<br />

The Initialization Value window contains the following parameters:<br />

Access Type: Only Write Multiple Register is allowed<br />

Register Offset: Offset of the %MW that will be initialized<br />

Length: Number of %MW that will be initialized. For example if Offset =2<br />

and Length = 3, %MW2, %MW3 and %MW4 wil be initialized<br />

Initialization Value: Value the registers are initialized with<br />

Comment: Add a comment about this initialization<br />

3 Click the Move up or Move down button to change the position of an<br />

initialization in the list.<br />

Click the Delete button to remove an initialization in the list.<br />

Click the Edit button to change the parameters of an initialization.<br />

4 Click OK to create a new Initialization Value.<br />

140 EIO0000000384 04/2012