Update the Firmware of the Loader Device Accessory<br />

Procedure<br />

Loader Device Accessory<br />

The following procedure describes how to update the Loader Device Accessory<br />

firmware:<br />

Step Action<br />

1 The USB memory key must only contain the following files:<br />

key.x.production.hex<br />

plc.x.production.hex<br />

Where x is the product firmware version.<br />

NOTE: Connect to www.schneider-electric.com to download the latest firmware<br />

update.<br />

2 Connect the USB memory key to the Loader Device Accessory.<br />

3 Move the Loader Device Accessory On/Off switch to the On position.<br />

4 At the end of the update (LED (see page 167) at Operation complete state),<br />

move the Loader Device Accessory On/Off switch to the Off position.<br />

5 Disconnect the USB key from the Loader Device Accessory.<br />

The Loader Device Accessory is automatically switched off<br />

after 10 s, if the update has been successfully completed.<br />

after 60 s, if the update has been unsuccessful.<br />

EIO0000000384 04/2012 179